We carry many different valves and components, including pressure regulators and flow meters. We offer many
options and styles to choose from.
CLICK HERE TO BROWSE OUR CATALOG
|
Why use a Pressure Regulator?
Reduces pressure to desired range for uniformity and safety.
- Assures desired pressure if the source fluctuates.
- Assures desired pressure in hilly terrain.
- Pressure must be greater than desired operating pressure.
- Flow rates must be within the limits of the regulator.
|
Why use Flow Meters?
Monitor water use for crop management
- Monitor system for plugging (lower flow rates)
- Monitor system for broken lines (higher flow rates)
- Overall system performance
- Helps with system troubleshooting
- Many styles available to fit the application
- Typically require 10 x 5 rule for installation (10 x pipe dia before and 5 x dia after meter of straight pipe
length).
Styles
- Pitot Tube: Reads instant flow no totalizer. Typically bolts onto the sidewall of the pipe and short tube
is inserted in a drilled hole in the side wall of the pipe. Good for trouble shooting and testing system performance.
- In-Line: Installed in-line typically bolt on or threaded style connections. Total waterflow passes through
the device spinning a turbine or impeller. Available with many register options.
- Bolt-on Saddle Type: Installed in-line by cutting a hole in the sidewall of the pipe with the turbine or impeller in the flow path.
|
Foot Valves
- Used to protect pump from large particles on the suction line side
- Helps to keep pump primed
- Self-cleaning available
- Many connection option (Threaded, Glue, Flange, OD Pipe)
- Different body materials (Aluminum, Stainless Steel, Brass, PVC, cast iron)
- Different mesh inlet screen sizes

|
AIR VENTS
Air vents help prevent collapsing lines, back siphoning, air pockets, and other problems associated with air in systems.
Sizes range from 1/2" -4"
Kinetic: Exhaust air at system start-up and allow air into the system at system shut-down.
Continuous: Exhausts air at system start-up and continues automatic air relief during operation. Not used as large volume air vent/vacuum.
Combo: Exhausts air at system start-up, continues to provide air relief during operation and allows air into system at system shut-down.

|
| |